Heater folgirovanny: IZOLAR-F, IZOLAR-LM

|
zolar-F –the made foam polyethylene duplicated by an aluminum (AL) foil. Thanks to high heat-insulating properties it is widely applied where house thermal insulation with high efficiency, the minimum expenses is necessary and at the minimum thickness of an insulating layer.
Izolar-LM – the made foam polyethylene duplicated by a mylar film with the metallized covering. The metallized film (lavsan) is applied in systems "Heat-insulated floors" since isn't affected by alkaline cement mortars. While the foil collapses at interaction with a cement coupler.
Reflects to 97% of infrared radiation, working by the principle of a thermos.
allows to reduce the volume of construction designs of walls, floors and a roof without loss of heattechnical characteristics.
it is easy-to-work also to installation. .
|

Scope Izolar NPE
Izolar -LM, Izolar-F —the universal heat-insulating material which main function is reflection of heat, and also protection against moisture, water and noise. Izolar-LM, Izolar-F allows at a small thickness and the minimum heatloss (the principle of a thermos) in the summer considerably to reduce an overheat under a roof, and not to pass cold air inside in the winter and not to let out warm outside. Izolar-LM, Izolar-F – thanks to the universal properties, opens unlimited opportunities of the use:
Cautions:
- Not to establish the made foam polyethylene near naked flame.
- Not to stack the made foam polyethylene on the chemical processed wooden surfaces before their full drying.
- Not to use the made foam polyethylene outside temperature condition: from –50 °C to +80 °C. Short-term use in temperature condition to +95 ° is allowed.
- Use of the made foam polyethylene in the open air on condition of full protection against hit of direct sunshine is allowed.
1. Isolation in Heat-insulated floor system
2. The warmed roof, penthouse, roof, attic
|
 
4-5мм ҡалынлыҡ тәҡдим ителә |
Internal finishing: gypsum cardboard, lining, plastic panels
Counterlath (wooden) Provides an air gap 1,5-2sm between isolation Izolar-LM (Izolar-F) and internal finishing.
Izolar-LM, Izolar-F is established on a wooden roofing battens of a design of a roof (on rafters) the reflecting party in the room. It is fixed by means of the construction stapler, small nails or self-tapping screws. Installation is conducted from below up by horizontal panels with joints not less 10sm. Joints connect the metallized (foiled ) adhesive tape.
Heater: minvata, expanded polystyrene, polyfoam
Rafter
Izolar And, Izolar AM - a vapor-permeable membrane for protection of a heater against external moisture.
Subpurlin or a continuous board flooring fastens on counterlaths.
Roofing material
|
|
|
3 Frame wall
4. Floor first floor
5. Warm balcony





the recommended thickness: the 4-10mm
6. Warming of hangars, warehouses, garages






the recommended thickness: the 5,8,10,20,50 mm
7. Isolation of air ducts in systems of ventilation



the recommended thickness: the 5, 8, 10mm
8 Screens behind heating radiators
9. Isolation of bodies automobile and trucks












10. Isolation of refrigeration units